A performance evaluation of filtered delay multiply and sum beamforming for ultrasound localization microscopy: preliminary results

Show simple item record

dc.contributor.author Madhavanunni, A. N.
dc.contributor.author Benoy, Niya Mariam
dc.contributor.author Panicker, Mahesh Raveendranatha
dc.contributor.author Shekhar, Himanshu
dc.contributor.other IEEE South Asian Ultrasonics Symposium (SAUS 2024)
dc.coverage.spatial India
dc.date.accessioned 2024-07-18T09:08:29Z
dc.date.available 2024-07-18T09:08:29Z
dc.date.issued 2024-03-27
dc.identifier.citation Madhavanunni, A. N.; Benoy, Niya Mariam; Panicker, Mahesh Raveendranatha and Shekhar, Himanshu, "A performance evaluation of filtered delay multiply and sum beamforming for ultrasound localization microscopy: preliminary results", in the IEEE South Asian Ultrasonics Symposium (SAUS 2024), Gandhinagar, IN, Mar. 27-29, 2024.
dc.identifier.uri https://doi.org/10.1109/SAUS61785.2024.10563635
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/10251
dc.description.abstract Ultrafast ultrasound localization microscopy (ULM), which has shown promising results in microvascular imaging, overcomes the typical trade-off between resolution and penetration depth. Combining ultrasound contrast agents and high frame rate imaging enables ULM to visualize microvasculature and quantify flow. However, the quality of the microvascular maps obtained depends on the signal-to-noise ratio of the received signals, image reconstruction techniques, and the microbubble (MB) localization and tracking algorithms used. Most reported research in ULM employs the conventional delay and sum (DAS) beamforming technique for image reconstruction despite its limited contrast and resolution. In this work, a filtered delay multiply and sum (F-DMAS) beamforming approach with non-steered plane wave transmit was employed for ULM, and its performance was compared with the conventional DAS-based approach for the different localization algorithms available in the Localization and Tracking Toolbox for Ultrasound Localization Microscopy. We also introduce two novel image quality measures that can overcome the limitations of conventional quality metrics that require suitable targets for evaluation. We also report the preliminary in-vitro investigation of F-DMAS with B-mode and power Doppler maps for microvascular imaging. The results are promising with enhanced contrast and lateral resolution, and suggest that further experimental studies are warranted.
dc.description.statementofresponsibility by A. N. Madhavanunni, Niya Mariam Benoy, Mahesh Raveendranatha Panicker and Himanshu Shekhar
dc.language.iso en_US
dc.publisher Institute of Electrical and Electronics Engineers (IEEE)
dc.subject Beamforming
dc.subject Delay multiply and sum
dc.subject Super-resolution
dc.subject Ultrasound localization microscopy
dc.title A performance evaluation of filtered delay multiply and sum beamforming for ultrasound localization microscopy: preliminary results
dc.type Conference Paper


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account