Use of stable isotopes for failure detection and tracing of biomaterials

Show simple item record

dc.contributor.advisor Misra, Superb K.
dc.contributor.author Malvi, Bharti
dc.date.accessioned 2024-09-13T08:19:24Z
dc.date.available 2024-09-13T08:19:24Z
dc.date.issued 2023
dc.identifier.citation Malvi, Bharti (2023). Use of stable isotopes for failure detection and tracing of biomaterials. Gandhinagar: Indian Institute of Technology Gandhinagar, 168p. (Acc. No.: T01148).
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/10435
dc.description.statementofresponsibility by Bharti Malvi
dc.format.extent xxix, 168p.: hbk.; 30 cm
dc.language.iso en_US
dc.publisher Indian Institute of Technology Gandhinagar
dc.subject High-Energy Ion Implantation Method
dc.subject Stainless Steel SS316L
dc.subject Polymethylmethacrylate (PMMA)
dc.subject Degradation-Biomedical Materials
dc.title Use of stable isotopes for failure detection and tracing of biomaterials
dc.type Thesis
dc.contributor.department Materials Engineering
dc.description.degree PhD