dc.contributor.author |
Pal, Uttam |
|
dc.contributor.author |
Nayak, Ashika |
|
dc.contributor.author |
Medisetti, Tejaswi |
|
dc.contributor.author |
Gogoi, Gayatri |
|
dc.contributor.author |
Shekhar, Himanshu |
|
dc.contributor.author |
Prasad, Msn |
|
dc.contributor.author |
Vaidya, Jayant S. |
|
dc.contributor.author |
Pandya, Hardik Jeetendra |
|
dc.coverage.spatial |
United States of America |
|
dc.date.accessioned |
2021-05-14T05:18:50Z |
|
dc.date.available |
2021-05-14T05:18:50Z |
|
dc.date.issued |
2021-12 |
|
dc.identifier.citation |
Pal, Uttam; Nayak, Ashika; Medisetti, Tejaswi; Gogoi, Gayatri; Shekhar, Himanshu; Prasad, Msn; Vaidya, Jayant S. and Pandya, Hardik Jeetendra, “Hybrid spectral-IRDx: near-IR and ultrasound attenuation system for differentiating breast cancer from adjacent normal tissue”, IEEE Transactions on Biomedical Engineering, DOI: 10.1109/TBME.2021.3077582, vol. 68, no. 12, pp. 3554-3563, Dec. 2021. |
en_US |
dc.identifier.issn |
0018-9294 |
|
dc.identifier.issn |
1558-2531 |
|
dc.identifier.uri |
https://doi.org/10.1109/TBME.2021.3077582 |
|
dc.identifier.uri |
https://repository.iitgn.ac.in/handle/123456789/6508 |
|
dc.description.abstract |
Objective: While performing surgical excision for breast cancer (lumpectomy), it is important to ensure a clear margin of normal tissue around the cancer to achieve complete resection. The current standard is histopathology; however, it is time-consuming and labour-intensive requiring skilled personnel. Method: We describe a Hybrid Spectral-IRDx - a combination of the previously reported Spectral-IRDx tool with multimodal ultrasound and NIR spectroscopy techniques. We show how this portable, cost-effective, minimal-contact tool could provide rapid diagnosis of cancer using formalin-fixed (FF) and deparaffinized (DP) breast biopsy tissues. Results: Using this new tool, measurements were performed on cancerous/fibroadenoma and its adjacent normal tissues from the same patients (N=14). The acoustic attenuation coefficient () and reduced scattering coefficient (s) (at 850, 940, and 1060 nm) for the cancerous/fibroadenoma tissues were reported to be higher compared to adjacent normal tissues, a basis of delineation. Comparing FF cancerous and adjacent normal tissue, the difference in s at 850 nm and 940 nm were statistically significant (p=3.17e-2 and 7.94e-3 respectively). The difference in between the cancerous and adjacent normal tissues for DP and FF tissues were also statistically significant (p=2.85e-2 and 7.94e-3 respectively). Combining multimodal parameters and s (at 940 nm) show highest statistical significance (p=6.72e-4) between FF cancerous/fibroadenoma and adjacent normal tissues. Conclusion: We show that Hybrid Spectral-IRDx can accurately delineate between cancerous and adjacent normal breast biopsy tissue. Significance: The results obtained establish the proof-of-principle and large-scale testing of this multimodal breast cancer diagnostic platform for core biopsy diagnosis. |
|
dc.description.statementofresponsibility |
by Uttam Pal, Ashika Nayak,Tejaswi Medisetti, Gayatri Gogoi, Himanshu Shekhar, Msn Prasad, Jayant S. Vaidya, Hardik Jeetendra Pandya |
|
dc.format.extent |
vol. 68, no. 12, pp. 3554-3563 |
|
dc.language.iso |
en_US |
en_US |
dc.publisher |
Institute of Electrical and Electronics Engineers |
en_US |
dc.subject |
Ultrasonic imaging |
en_US |
dc.subject |
Ultrasonic variables measurement |
en_US |
dc.subject |
Optical attenuators |
en_US |
dc.subject |
Biopsy |
en_US |
dc.subject |
Biomedical optical imaging |
en_US |
dc.subject |
Optical imaging |
en_US |
dc.subject |
Acoustic measurements |
en_US |
dc.title |
Hybrid spectral-IRDx: near-IR and ultrasound attenuation system for differentiating breast cancer from adjacent normal tissue |
en_US |
dc.type |
Article |
en_US |
dc.relation.journal |
IEEE Transactions on Biomedical Engineering |
|