Systematic quantification of differences in shear wave elastography estimates between linear-elastic and viscoelastic material assumptions

Show simple item record

dc.contributor.author Bisht, Sapna R.
dc.contributor.author Paul, Abhijit
dc.contributor.author Patel, Panchami
dc.contributor.author Thareja, Prachi
dc.contributor.author Mercado-Shekhar, Karla P.
dc.coverage.spatial United States of America
dc.date.accessioned 2024-03-20T14:30:46Z
dc.date.available 2024-03-20T14:30:46Z
dc.date.issued 2024-03
dc.identifier.citation Bisht, Sapna R.; Paul, Abhijit; Patel, Panchami; Thareja, Prachi and Mercado-Shekhar, Karla P., "Systematic quantification of differences in shear wave elastography estimates between linear-elastic and viscoelastic material assumptions", The Journal of the Acoustical Society of America, DOI: 10.1121/10.0025291, vol. 155, no. 3, pp. 2025-2036, Mar. 2024.
dc.identifier.issn 0001-4966
dc.identifier.uri https://doi.org/10.1121/10.0025291
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/9865
dc.description.abstract Quantitative, accurate, and standardized metrics are important for reliable shear wave elastography (SWE)-based biomarkers. For over two decades, the linear-elastic material assumption has been employed in SWE modes. In recent years, viscoelasticity estimation methods have been adopted in a few clinical systems. The current study aims to systematically quantify differences in SWE estimates obtained using linear-elastic and viscoelastic material assumptions. An acousto-mechanical simulation framework of acoustic radiation force impulse-based SWE was created to elucidate the effect of material viscosity and shear modulus on SWE estimates. Shear modulus estimates exhibited errors up to 72% when a numerical viscoelastic phantom was assessed as linearly elastic. Shear modulus estimates of polyvinyl alcohol phantoms between rheometry and SWE following the Kelvin-Voigt viscoelastic model assumptions were not significantly different. However, the percentage difference in shear modulus estimates between rheometry and SWE using the linear-elastic assumption was 50.1%–62.1%. In ex vivo liver, the percentage difference in shear modulus estimates between linear-elastic and viscoelastic methods was 76.1%. These findings provide a direct and systematic quantification of the potential error introduced when viscoelastic tissues are imaged with SWE following the linear-elastic assumption. This work emphasizes the need to utilize viscoelasticity estimation methods for developing robust quantitative imaging biomarkers.
dc.description.statementofresponsibility by Sapna R. Bisht, Abhijit Paul, Panchami Patel, Prachi Thareja and Karla P. Mercado-Shekhar
dc.format.extent vol. 155, no. 3, pp. 2025-2036
dc.language.iso en_US
dc.publisher Acoustical Society of America
dc.title Systematic quantification of differences in shear wave elastography estimates between linear-elastic and viscoelastic material assumptions
dc.type Article
dc.relation.journal The Journal of the Acoustical Society of America


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account